Severity: Warning
Message: fopen(/var/cpanel/php/sessions/ea-php80/ci_sessionb221fc20353d684349e919625e8a7781a66d72b8): Failed to open stream: Disk quota exceeded
Filename: drivers/Session_files_driver.php
Line Number: 179
Backtrace:
File: /home/labotest/public_html/visionbiomed.com/application/controllers/Home.php
Line: 6
Function: __construct
File: /home/labotest/public_html/visionbiomed.com/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_start(): Failed to read session data: user (path: /var/cpanel/php/sessions/ea-php80)
Filename: Session/Session.php
Line Number: 143
Backtrace:
File: /home/labotest/public_html/visionbiomed.com/application/controllers/Home.php
Line: 6
Function: __construct
File: /home/labotest/public_html/visionbiomed.com/index.php
Line: 315
Function: require_once
Anaesthesia System KAM-A200 is equipped with LED screen for clear display of trends, dosage rate and other setting parameters. System complies with closed, semi-closed, semi-open ventilation. Fully integrated pneumatically driven electronic system offers 3 ventilation modes with specialized CO2 absorber based breathing systems. Comprehensive alarm indication for critical events increases patient safety.
Drive | Electronically controlled, pneumatic driven |
Tidal Volume | 0 ml ~ 1500 ml |
Ventilation Modes | A/C, IPPV, SIPPV, Manual |
Gas Configuration | O2, N2O |
LCD Display | LED display screen |
Vaporizer | Isoflurane / Enflurane |
Medical Gas Pressure Range | 0.32 mPa ~ 0.6 mPa |
Air Pressure Range | 0.32 mPa ~ 0.5 mPa |
Maximum Safety Pressure | ≤ 12.5 kPa |
I:E Range | 1:1.5 ~ 1:1.3 |
O2 Flush | 25 L/min ~ 75 L/min |
O2 Concentration | > 21% |
Respiration Rate | 4 bpm ~ 40 bpm |
Error Tolerance | ≤ ± 4 % |
O2 Flow meter | 0.1 L/min ~ 10 L/min |
N2O Flow meter | 0.1 L/min ~ 10 L/min |
Pressure Safety Valve | <12.5 k Pa |
Airway Pressure Alarm | Lower limit 0.2 kPa ~ 5 kPa Upper limit 0.3 kPa ~ 6 kPa |
Tidal Volume Alarm | Lower limit 0 ml ~ 1800 ml Upper limit 50 ml ~ 2000 ml |
Ventilation Volume Alarm | Lower limit 0 L/ml ~ 12 L/ml Upper limit > 18 L/ml |
CO2 Absorber | Soda lime tank |
Storage: Ambient Temperature | -15°C to 50°C |
Storage: Relative Humidity | < 95% |
Storage: Atmospheric Pressure | 86 kPa ~ 106 kPa |
Power Supply | 100 V ~ 120 V AC, 50/60 Hz |
Dimension | 830 x 770 x 1230 mm |
Weight | 75 Kgs |
Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.