A PHP Error was encountered

Severity: Warning

Message: fopen(/var/cpanel/php/sessions/ea-php80/ci_sessionb221fc20353d684349e919625e8a7781a66d72b8): Failed to open stream: Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 179

Backtrace:

File: /home/labotest/public_html/visionbiomed.com/application/controllers/Home.php
Line: 6
Function: __construct

File: /home/labotest/public_html/visionbiomed.com/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/cpanel/php/sessions/ea-php80)

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home/labotest/public_html/visionbiomed.com/application/controllers/Home.php
Line: 6
Function: __construct

File: /home/labotest/public_html/visionbiomed.com/index.php
Line: 315
Function: require_once

Vision Bio Med
Anaesthesia System KAM-A200

Anaesthesia System KAM-A200

Anaesthesia System KAM-A200 is equipped with LED screen for clear display of trends, dosage rate and other setting parameters. System complies with closed, semi-closed, semi-open ventilation. Fully integrated pneumatically driven electronic system offers 3 ventilation modes with specialized CO2 absorber based breathing systems. Comprehensive alarm indication for critical events increases patient safety.

Catalog

Features:

  • Pneumatic controlled flow
  • Ventilation modes: A/C, IPPV, SIPPV, Manual
  • Vaporizer : Enflurane/Isoflurane
  • Dual flow-meter
  • Suitable for adult as well as pediatric care
  • Patient monitor (optional)

Specifications

Drive

Electronically controlled, pneumatic driven

Tidal Volume

0 ml ~ 1500 ml

Ventilation Modes

A/C, IPPV, SIPPV, Manual

Gas Configuration

O2, N2O

LCD Display

LED display screen

Vaporizer

Isoflurane / Enflurane

Medical Gas Pressure Range

0.32 mPa ~ 0.6 mPa

Air Pressure Range

0.32 mPa ~ 0.5 mPa

Maximum Safety Pressure

≤ 12.5 kPa

I:E Range

1:1.5 ~ 1:1.3

O2 Flush

25 L/min ~ 75 L/min

O2 Concentration

> 21%

Respiration Rate

4 bpm ~ 40 bpm

Error Tolerance

≤ ± 4 %

O2 Flow meter

0.1 L/min ~ 10 L/min

N2O Flow meter

0.1 L/min ~ 10 L/min

Pressure Safety Valve

<12.5 k Pa

Airway Pressure Alarm

Lower limit 0.2 kPa ~ 5 kPa
Upper limit 0.3 kPa ~ 6 kPa

Tidal Volume Alarm

Lower limit 0 ml ~ 1800 ml
Upper limit 50 ml ~ 2000 ml

Ventilation Volume Alarm

Lower limit 0 L/ml ~ 12 L/ml
Upper limit > 18 L/ml

CO2 Absorber

Soda lime tank

Storage: Ambient Temperature

-15°C to 50°C

Storage: Relative Humidity

< 95%

Storage: Atmospheric Pressure

86 kPa ~ 106 kPa

Power Supply

100 V ~ 120 V AC, 50/60 Hz

Dimension

830 x 770 x 1230 mm

Weight

75 Kgs

Applications:

Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.